Philips HP 50XM M1360b Fetal Monitor
The HP/Philips Fetal Monitor Series 50XM is a high-quality unit utilized during delivery and labor. It provides continuous maternal vital signs monitoring and maternal non-invasive blood pressure readings. It features individual twin’s heart rate monitoring as well as uterine activity calculated in relation to a selected baseline. The 50XM
provides signal quality indicators for each fetal heart channel for optimal transducer placement. The color-coded sockets match the transducer cables for easy identification.
- Continuous maternal vital signs monitoring, and maternal non-invasive blood pressure
- Individual twins heart rate monitoring
- Uterine activity calculated in relation to a selected baseline
- Signal quality indicators for each fetal heart rate channel for optimal transducer placement
- Toco and intrauterine pressure monitoring
- Color-coded sockets match transducer cables.
Philips HP 50 XM Specifications
Dimensions
- Height: 5.8 in (147mm)
- Width: 16.6 in (422 mm)
- Depth: 15.4 in (392mm)
- Weight: 31.96 lbs (14.6 kg)
Environmental
- Operating Temperature: 0°C to + 55°C
- Storage Temperature: -40°C to +75°C
- Relative Humidity: 5% to 95%
Fetal Display
- Heart Rate Range
- US: 50 to 240 bpm
- DEGG: 30 to 240 bpm
- MHR: 30 to 240bpm (not displayed)
- External Toco Range: 0 to + 127 relative units
- IUP Range: -99 to 127 mmHg
- Fetal SpO2 Range: 0-99%
- Fetal Heart Rate Alarm Limits
- Bradycardia Alert Range: 60 to 120 bpm Adjustable in 10 bpm steps (default: 110 bpm)
- Tachycardia Alert Range: 150 to 210 bpm adjustable in 10 bpm stems (Default: 150 bpm)
- Fetal Heart Rate alarm Delay
- Bradycardia Alert Delay: 10 to 300 sec adjustable in 10 sec steps (Default: 60 sec)
- Tachycardia Alert Delay: 10 to 300 sec adjustable in 10 sec steps (Default: 60 sec)
Maternal non invasive Blood Pressure
- Pressure Transducer Accuracy:
- 15°C to 25°C ±3 mmHg
- 10°C to 35°C ±3 mmHg (±0.6% of reading)
- 0°C to 55°C ±3 mmHg (±1.7% of reading
- Measurement Range:
- Systolic: 30 to 270 mmHg
- Diastolic: 10 to 245 mmHg
- Cuff inflation rate: typically less than 10 seconds
- Auto Mode Repetition time: 2, 5, 10, 15, 30, 60 minutes
- Start Mode Duration: 5 minutes
- Pulse Rate Range: Measurable within heart rate range of 30 to 240 bpm, averaged during NIBP measurement.
Power Requirements
- Operating Voltage
- 100 – 120 V (± 10%)
- 220 – 240 V (±10%)
- Line Frequency 50 to 60 Hz
- Power Consumption 60 VA max
Fetal Display
- Heart Rate Range
- US 50 to 240 bpm
- DECG 30 to 240 bpm
- MHR 30 to 240 bpm (not displayed)
- External Toco Range 0 to +127 relative units
- IUP Range -99 to +127 mmHg
- Fetal SpO2 Range 0 – 99%
Maternal Pulse Oximetry
- Percentage Range 0 to 100%
- BPM Range 30 to 300 bpm
- Accuracy ± 1%
- Resolution 1 bpm
- Pulse Rate Limit Alarms
- Range 70% – 90%
- Adjustment 1% steps
- Accuracy at 1 standard deviation
- M1191A 70 to 99% ± 2.5%
- M1192A 70 to 99% ± 2.5%
- M1194A 70 to 99% ± 4%
- Nellcor sensors 80 to 99% ± 3%
Maternal ECG and Heart Rate
- Heart Rate Measurement
- Range 30 to 240 bpm
- Accuracy ±1 bpm
- Display Resolution: 1bpm
- Recorder Resolution: 0.25bpm
- Heart Rate Alarm Limits (excluding NIBP)
- Range 30 to 250 bpm
- Adjustment 5 bpm steps